Model No. DF 301

Home / Medical Equipments & Home Health Care Products / Defibrillator / Model No. DF 301
Product Description
  • Input : 150~270 VAC , 50Hz 
  • Battery - 12V, 4.5Ah, Rechagable Battery Capacity 3 hours For monitor & 70~100 Shocks on single Charge
  • Charging time less than 6 Seconds
  • Operation-by Front Panal Key board, Encoder & ON-Off  By front Panel Push Button
  • Display : 7" Colour TFT with ECG display and printer / Recorder
  • Input : 150 ~ 276 VAC, 50 Hz
  • Output : 17V at 4A
  • Power Consumption : 30 Watts (Max) in ECG mode
  • Operating Temp : -5°C to +50°C
  • Humidity : up to 95% non condensing
  • Rechargeable lithium battery with charger (11.1V)
  • LED Indicator : Low battery and battery charging
DEFIB
  • Operating Mode : Manual
  • Waveform : Biphasic
  • Energy : 2 to 200 joules in 12 Steps [2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200 Joules]
  • Adult and Paediatric paddles support
  • Charging Time : less than 8sec
  • Synchronous: Energy delivery begins within
    60ms of the QRS Peak
  • Paddle Assembly: Energy paddle assembly with
    coil retractable high voltage cable
  • Adults & Paediatric paddle integrated to same handle
  • Check mode : Manual test mode
AED Mode
  • Waveform : Bi Phasic
  • AEC Shock series : Energy level from 150 to 200J
  • Charge command automatic after identifying arrhythmia
  • Shock Command : Front panel button, Shock
  • Charging Time : Less than 7 seconds
  • Controls : Analyze, Pause
  • Defibrillation Electrode : Malfunction, Self Adhesive, Adult electrodes
  • Voice and Text Prompts : Voice and text prompts to guide user
SpO2 (Optional)
  • Pitch Variation with change in oxygen saturation
  • Range : 0 ~ 100%
  • Accuracy : 70 ~ 100% ±2%, 50 ~ 69% ±3%
  • Pulse rate : displayed when PR is deselected
  • Pulse Beep : Step less volume control
  • PR Range : 10 ~ 250 bpm
  • Pitch Variation with change in oxygen saturation
Pacemaker (Optional)
  • Waveform: Monophasic
  • Modes: Demand or Non Demand
  • Amplitude: From 10mA to 150mA (Resolution of 10mA)
  • Pulse Width: 40ms (± 1ms) 
  • Frequency: From 20ppm to 250ppm (increments of 1ppm)
  • Refectory period: 340ms (from 30 to 80ppm), 240ms (from 90 to 180ppm)
  • Maximum Output Voltage: 150V
  • Impedance Range: 200Ω to 1kΩ
PRINTER
  • Paper Type : Thermal paper 50/55mm width, 20
    meters length for 2 inch printer
  • Event Printing : Prints 5 seconds pre & post ECG with
    Date, Time, Energy and mode, Shock Status
  • ECG in Defib Mode : Prints last 10 sec ECG through
    paddle
  • Print Annotates in Defib mode : Time, Date, Mode,
    Lead name ,Gain, Sweep Speed
  • ECG in Monitor mode : Prints last 10 sec ECG through
    paddle
  • Print Annotates in Monitor mode : Time, Date,
    Selected Lead name, Gain, Sweep Speed
  • Manual Defib Check Mode: Print the status of Shock,
    Energy, Date and Time
NIBP (Optional)
  • Method : Oscillometric
  • NIBP Interval : User Selectable — 3 min to 120 min
  • Modes : Manual, Auto
  • Cuff Deflation : Automatic
  • Safety Features : Automatic deflation if cuff pressure exceeds 280 mmHg
  • Range : 10 ~ 250 mmHg
  • NIBP Status : “Ready” — When not taking reading “Measuring”— When taking reading “Error” — if reading could not be taken due to some error while measuring
  • Patient Type : Adult, Paediatric, Neonate